danaxwire.blogg.se

Diebold Atm Manual
diebold atm manual













Diebold technol- Manual insert (dip). The very effective collaboration was carried out in recent months between the ATM experts of Cr&233 dit Mutuel Alliance F&233 d&233 rale and Diebold Nixdorf allowing the successful start of our first. DN Series provides the ability to grow with your strategy and deliver the most integrated functionality in the smallest, most secure footprint.

An automated teller machine (ATM) or cash machine (in British English) is an electronic. Diebold Service Manual 109 Series Power Shelf Files. Diebold Service Manual Open Shelf Power Filing. Diebold 49-219660-000b Opteva Atm Power Control Panel Box Module On/off Switch. Diebold Opteva ATM Training Manual.A Using the Operator Panel of a Diebold Opteva ATMDiebold Atm Power Cable Harness 49-211500-000a Dist Board To Usb Hub To Power.

Find the mode rocker switch, located behind the fascia at the top right of the enclosure. The lock is located on the upper left fascia panel. Insert the key and unlock and pull open the front fascia of the ATM. To activate the Onscreen Operator Panel (OOP), follow these steps: 1. The system keyboard (available inside the ATM cabinet) is used in conjunction with the ROP for performing operator functions.On Opteva front-service models, which have no separate display panel, the customer display is used for operator functions.

Significant differences are noted where applicable.This appendix is organized as follows: NOTE NOTE NOTE ROP and OOP layout ROP and OOP commands ROP and OOP display states (Section G.1) (Section G.2) (Section )ROP and OOP LayoutThe top line of the operator panel display is the Overall State Description, and is an abbreviated text description describing the current state of the ATM. Keep in mind that there are some minor differences in the way that the operator interacts with these applications due to the differing input methods. For security reasons, if the front fascia of the ATM is closed while the OOP is still activated, the command buttons are disabled.All the instructions in this appendix apply to both the ROP and OOP because they are functionally equivalent. The Touch Screen is used for operator input and the system keyboard is not needed for most operations. Holding down the mode switch again returns the main display to the Hello screen (or the Out-of-Service screen if the ATM is not in Up state).

Select the Confirm button (the Y key for the ROP) to confirm the selection or the Cancel button (the N key for the ROP) to cancel the selection. The bottom line of the operator panel displays the Citibank logo on the left and the node ID on the right.ROP and OOP CommandsThe following commands are available from both the ROP and the OOP: Shutdown Reboot Diagnostics Front Logon Calibrate Touch ScreenWhen a command is selected, a confirmation window is displayed. This area remains blank if there are no outstanding errors or warnings. The next eight lines of the operator panel are reserved for any specific device errors or warnings.

Diebold Atm Software Starts Loading

Eventually, the ROP will display the Out-Of-Service screen for a few minutes until the Global CAT software starts loading.Provides the operator a way to start the Diebold Opteva diagnostic application.Procedure:Select Diagnostics from the command list and confirm it. If a customer is not in session at the time of the request, the front screen of the ATM will go to the Out-Of-Service screen and the ROP will look like this:The front screen of the ATM will eventually show that the system is rebooting and the Windows XP operating system shutting down and then booting up. It is then safe to power off the ATMs peripheral devices.Provides the operator a way to properly reboot the ATM.Procedure:Select Reboot from the command list and confirm it. The systems processing engine will power off automatically. On rear-service systems, the ROP will also go blank. If a customer is not in session at the time of the request, the front screen of the ATM will go to the Out-Of-Service screen and the ROP will look like the following example screen:After the system successfully shuts down the Global CAT ATM and the Windows XP operating system (approximately 45-55 seconds), the front screen will go blank.

diebold atm manual

FrontOI Command failed - Remote OI already active. Possible causes for failure are: FrontOI Command failed - ATM is wrong state. Upon exit of Local OI, the OOP will again be visible and display the appropriate ATM state.After the operator has successfully logged on to Front OI, the ROP looks like the following example screen:If the ATM rejects the command request, one of several possible messages is displayed, indicating the cause of the failed request.

diebold atm manual

No commands are available in this state.StoppedThis mode is displayed when the ATM has finished stopping after a Stop command has been issued to a Global CAT ATM. It is a transitional state and should not take more than 30 seconds or so to get to the Stopped state. No commands are available in this state.StoppingThis mode is displayed when a Stop, Shutdown, or Reboot command has been issued to a Global CAT ATM. The Start command is issued only from the Operator Interface (Local or Remote) and the INC. It is a transitional state and should not take more than 30 seconds or so to get to the Out-Of-Service state.

All commands are available in this state.The Diebold Opteva ATM defines Device Warning information that must be communicated to the operations and maintenance personnel for proper and efficient ATM operation. This is the normal state of the ATM when no customer session is active. No commands are available in this state.IdleThis mode is displayed when the ATM is at the Hello screen. All commands are functional in this state.Back Admin ActiveThis mode is displayed when Back Admin is currently active on a Remote OI terminal.

diebold atm manual